Microorganism Corrosion and the Measure of the Concrete in the
Sewerage System
By F. Mishina
Concrete Journal, Vol.41, No.10, Oct. 2003
- Synopsis
- It is a cause that the concrete corrosion of the sewerage system is the microorganism corrosion that originates from the sulfuric acid and hydrogen sulfide that are included in the sewer. Therefore the corrosion is seen several centimeters in the several years and the development of the measure and new material are requested.
- Keywords:
- sulfuric acid, hydrogen sulfide, resistance acid cincrete, corrosion protection sewerage