Reinforcing Method for Opening at Plastic Hinge Areas in R/C Beams
By R. Suruga, T. Morimoto, K. Yamamoto and T. Watanabe

Concrete Journal, Vol.40, No.8, Aug. 2002


Synopsis
It is not allowed to make openings to run pipes through in plastic hinge area of reinforced concrete beam. If it is allowed, a possibility of design will insrease. This paper reports on the shear/bending test under reversed cyclic loading of reinforced concrete beam with opening at plastic hinge area. This reinforcement for opening is characterized by "II"-shaped bucking reinforcement. As a result, the flexural strength and deformability of R/C beams with opening were on a par with no opening R/C beams.
Keywords:
reinforced concrete beam, opening reinforcement, bucking reinforcement, plastic hinge area, flexural strength, deformability, shear/bending test

To Pagetop