Reinforcing Method for Opening at Plastic Hinge Areas in R/C Beams
By R. Suruga, T. Morimoto, K. Yamamoto and T. Watanabe
Concrete Journal, Vol.40, No.8, Aug. 2002
- Synopsis
- It is not allowed to make openings to run pipes through in plastic hinge area of reinforced concrete beam. If it is allowed, a possibility of design will insrease. This paper reports on the shear/bending test under reversed cyclic loading of reinforced concrete beam with opening at plastic hinge area. This reinforcement for opening is characterized by "II"-shaped bucking reinforcement. As a result, the flexural strength and deformability of R/C beams with opening were on a par with no opening R/C beams.
- Keywords:
- reinforced concrete beam, opening reinforcement, bucking reinforcement, plastic hinge area, flexural strength, deformability, shear/bending test